Add to Cart
10KW SOLAR POWER SYSTEM It is the abbreviation of Solar Power System. It is a new type of power generation system that uses the photovoltaic effect of solar cell semiconductor materials to directly convert solar radiation energy into electrical energy. There are two types of independent operation and grid-connected operation. If you are interested in any of our products, please contact us in time, I believe we can cooperate happily.
Model | 30 50 100 120 150KW | ||||
Hybrid Inverter( KW) | 30KW | 50KW | 100KW | 120KW | 150KW |
550W Mono Solar Panel (Pcs) | 56 | 96 | 200 | 240 | 280 |
PV Combiner Box (Set) | 1 | 1 | 1 | 1 | 1 |
Lead Acid Gel/ AGM Battery | 336V-438V 200Ah | 336V-438V 200Ah | 336V-438V 200Ah | 336V-438V 200Ah | 336V-438V 200Ah |
Quantity of Battery (Pcs) | 1 | 2 | 4 | 4 | 6 |
DC Cable (m) | 400 | 600 | 800 | 800 | 1000 |
AC (Grid-connected) | ATESS HPS30 | ATESS HPS50 | ATESS HPS100 | ATESS HPS120 | ATESS HPS150 |
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
Rated current | 43A | 72A | 144A | 173A | 217A |
AC input | 60kVA | 100kVA | 200kVA | 240kVA | 240kVA |
Voltage range | 360V - 440V | ||||
Rated voltage | 400V | ||||
Rated frequency | 50/60Hz | ||||
Frequency range | 45~55/55~65Hz | ||||
THDI | <3% | ||||
PF | 0.8lagging~0.8leading | ||||
AC connection | 3/N/PE | ||||
AC(Off-grid) | |||||
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
Rated voltage | 400V | 400V | 400V | 400V | 400V |
Rated current | 43A | 72A | 144A | 173A | 217A |
THDU | ≤2%linear | ||||
Rated frequency | 50/60Hz | ||||
Overload capability | 110%-10 mins 120%-1 min | ||||
DC (Battery and PV) | |||||
Max PV open-circuit voltage | 1000V DC | 1000V DC | 1000V DC | 1000V DC | 1000V DC |
MAX PV power | 45kWp | 75kWp | 150kWp | 180kWp | 225kWp |
PV MPPT voltage range | 480V-800V DC | 480V-800V DC | 480V-800V DC | 480V-800V DC | 480V-800V DC |
Battery voltage range at Max.charge power | 450V-600V | 500V-600V | 500V-600V | 517V-600V | 500V-600V |
Battery voltage range | 352-600V | 352-600V | 352-600V | 352-600V | 352-600V |
Max.charge power | 45kW | 75kW | 150kW | 180kW | 225kW |
Max.discharge power | 33kW | 55kW | 110kW | 132kW | 165kW |
Max.charge current | 100A | 150A | 300A | 350A | 400A |
Max.discharge current | 93A | 156A | 313A | 374A | 467A |
The working principle of crystalline silicon n/p-type solar cells: When a p-type semiconductor and an n-type semiconductor are tightly combined into one piece, a p-n junction is formed at the interface between the two. When the photovoltaic cell is irradiated by sunlight, the accumulation of positive and negative charges is formed on both sides of the p-n junction, a photovoltaic voltage is generated, and a built-in electric field is formed. This is the "photovoltaic effect." Theoretically speaking, at this time, if electrodes are drawn on both sides of the built-in electric field and an appropriate load is connected, a current will be formed and power will be obtained from the load. Solar cell modules are solid-state devices that use the electronic properties of semiconductor materials to achieve P-V conversion.
Family Emergency;Commercicl Emergency;Industrial Emergency;Travel
1. There is a countercurrent grid-connected photovoltaic power generation system
2. Grid-connected photovoltaic power generation system without countercurrent
3. Switching grid-connected photovoltaic power generation system
4. Grid-connected photovoltaic power generation system with energy storage device