Add to Cart
Solar panel is a device that directly or indirectly converts solar radiation energy into electrical energy through photoelectric effect or photochemical effect by absorbing sunlight. The main material of most solar panels is "silicon", but the cost of production is relatively high. It is so large that it has certain limitations in its universal use. Compared with ordinary batteries and rechargeable batteries, solar batteries are more energy-saving and environmentally friendly green products.
ELE CTRIC AL PERF ORMANCE
Electrical parameters at Standard Test Conditions (STC) | ||||||
Module type | | | AYxxxD-40d 1/2 (xxx=Pmax) AYxxxD-40d 1500V 1/2 (xxx=Pmax) | |||
Power output | Pmax | W | 435 | 440 | 445 | 450 |
Power output tolerances | ΔPmax | W | 0/+5 | |||
Module efficiency | ηm | % | 20.01 | 20.24 | 20.47 | 20.70 |
Voltage at Pmax | Vmpp | V | 40.75 | 40.95 | 41.15 | 41.35 |
Current at Pmax | Impp | A | 10.68 | 10.75 | 10.82 | 10.89 |
Open-circuit voltage | Voc | V | 49.30 | 49.50 | 49.70 | 49.90 |
Short-circuit current | Isc | A | 11.26 | 11.33 | 11.40 | 11.47 |
STC: 1000W/m2 irradiance, 25°C module temperature, AM1.5g spectrum according to EN 60904-3. Average relative efficiency reduction of 3.3% at 200W/m2 according to EN 60904-1.
Electrical parameters at Nominal Operating Cell Temperature (NOCT) | ||||||
Power output | Pmax | W | 322.2 | 326.0 | 329.7 | 333.4 |
Voltage at Pmax | Vmpp | V | 37.7 | 37.9 | 38.1 | 38.3 |
Current at Pmax | Impp | A | 8.54 | 8.60 | 8.66 | 8.71 |
Open-circuit voltage | Voc | V | 46.0 | 46.2 | 46.3 | 46.5 |
Short-circuit current | Isc | A | 9.12 | 9.17 | 9.23 | 9.29 |
NOCT: open-circuit module operation temperature at 800W/m2 irradiance, 20°C ambient temperature,
1m/s wind speed.
THERMAL CHAR ACTERISTICS
Nominal operating cell temperature | NOCT | °C | 45± 2 |
Temperature coefficient of Pmax | γ | %/°C | -0.37 |
Temperature coefficient of Voc | βVoc | %/°C | -0.29 |
Temperature coefficient of Isc | αlsc | %/°C | 0.06 |
OPER ATING CONDITIONS
Max. system voltage | 1000VDC or 1500VDC |
Max. series fuse rating | 20A |
Operating temperature range | -40°C to 85°C |
Max. static load, front (e.g., snow) | 5400Pa |
Max. static load, back (e.g., wind) | 2400Pa |
Max. hailstone impact (diameter / velocity) | 25mm / 23m/s |
*DO NOT connect Fuse in Combiner Box with two or more strings in parallel connection
CONSTRUCTION MATERIALS
Front cover (material / thickness) | low-iron tempered glass / 3.2mm |
Cell (quantity / material ) | 144 / monocrystalline silicon |
Frame (material ) | anodized aluminum alloy |
Junction box (protection degree) | ³ IP67 |
Cable (length / cross-sectional area) | 400(300)mm / 4mm2 |
Higher Durability
The multi-busbar design can decrease the risk of the cell micro- cracks and fingers broken.
High Power Density
High conversion efficiency and more power output per square meter, by lower series resistance and improved light harvesting.
Half-cell Design
Less energy loss cased by shading due to new cell string layout and split J-box, and lower cell connection power loss due to half-cell design.
Advanced Glass
Our high-transmission glass features a unique anti-reflective coating that directs more light on the solar cells, resulting in a higher energy yield.
a. User solar power supply
b. the field of transportation
c. Communication/communication field
d. Petroleum, Marine and meteorological fields
e. the power supply of household lamps and lanterns
f. Photovoltaic power station
g. solar energy building
PACKAGING SPE CIFIC ATIONS
Number of modules per pallet | 30 |
Number of pallets per 40’ container | 22 |
Packaging box dimensions (L / W / H) | 2135mm / 1110mm / 1190mm |
Box weight | 745 kg |